Hydrogen Safety
Introduction of hydrogen
risk awareness

Drs. Ing. J.M.M. Bruijnen MSc TQM
SBVM
Safety Engineer – level 3 (HVK) Member Hysafe Partner van Center for Hydrogen Safety

RISK AWARENESS HYDROGEN SAFETY
November 12th 2019 Delft University of Technology.

Mr A.W.T. Niehof, LLM - Programme Director
Drs Ing J.M.M. Bruijnen, MSc, HVK Dipl - Course Director 2

Royal Netherlands Navy

Hydrogen Safety
Full text, so the search can find this document · 15 kB of text
Topics
• Introduction Safety Policy Royal Dutch Navy • Atomic Structure Hydrogen • Physical properties Hydrogen • Hydrogen Hazards • AtEx requirements • Hazardous Area classification • Hazard identification method (Know the hazards, understand the risks) • Explosion Safety Documentation 3

Royal Netherlands Navy
Hydrogen Safety

Introduction

Safety Aspects of Hydrogen as an Energy Carrier

4

Royal Netherlands Navy
Hydrogen Safety

Policy Safety & Environment
Royal Dutch Navy
•

Optimum reduction of risks to loss
of life, injury and property damage.

•

Ensure a SAFE working environment.

•

Honor mutual agreement on
establishing a safety culture.

•

Learn from mistakes.

•

Be Pro active.

•

Be Compliant with law, legislation
and best practices.

5

Royal Netherlands Navy
Hydrogen Safety

Energy transition
Fossil => Sustainable fuels
OES ambition Department of Defense:
Reduction of fossil fuel consumption with:
• 20% in 2030 • 50% in 2050

6

Royal Netherlands Navy
Hydrogen Safety

Atomic Structure Hydrogen

7

Royal Netherlands Navy
Hydrogen Safety

Hydrogen is the chemical element with the symbol H and atomic number 1. With a standard atomic weight of 1.008, hydrogen is the lightest element in the periodic table.
Hydrogen is the most abundant chemical substance in the Universe, constituting roughly 75% of all baryonic mass.[7][note 1] Non-remnant stars are mainly composed of hydrogen in the plasma state.
https://en.wikipedia.org/wiki/Hydrogen

8

Royal Netherlands Navy
Hydrogen Safety

The most common isotope of hydrogen,
termed protium (name rarely used, symbol 1H), has one proton and no neutrons.
Other forms of isotopes are:
• Deuterium • Tritium

Ref: https://nl.wikipedia.org/wiki/Diwaterstof

Figuur 1 Ortho en Para waterstof
9

Royal Netherlands Navy
Hydrogen Safety

Hydrogen and Periodic Table

10

Royal Netherlands Navy
Hydrogen Safety

Hydrogen Phase envelop

11

Royal Netherlands Navy
Hydrogen Safety

12

Royal Netherlands Navy
Hydrogen Safety

Physical properties
Ref: H2Tools.org ER training

13

Royal Netherlands Navy
Hydrogen Safety

Hydrogen Properties and Behavior
A gas at ambient conditions Hydrogen is a cryogen: exists as a liquid at -423°F (-253°C).


Compressing the gas does not liquefy it



No liquid phase in a compressed gaseous hydrogen storage tanks

LH2 storage at relatively low pressure (50 psi) Double walled, vacuum insulated tanks with burst disks, vents, and PRDs Molecular Hydrogen

Volumetric ratio of liquid to gas is 1:848


Compare water to steam (1:1700)

Energy content of 1kg of H2 is approximately equal to 3.5 ltr of gasoline (in BTUs) 14

Royal Netherlands Navy
Hydrogen Safety

Hydrogen Properties: A Comparison
Hydrogen

Natural Gas

Gasoline

Color

No

No

Yes

Toxicity

None

Some

High

Odor

Odorless

Mercaptan

Yes

Buoyancy
Relative to Air

14X
Lighter

2X
Lighter

3.75X
Heavier

Energy
by Weight

2.8X
> Gasoline

~1.2X
> Gasoline

43 MJ/kg

Energy
by Volume

4X
< Gasoline

1.5X
< Gasoline

120 MJ/Gallon

Source: California Fuel Cell Partnership
15

Royal Netherlands Navy
Hydrogen Safety

Comparison of Fuel Odorants and Toxicity
Fuels

Odorant Added?

Toxic?

Hydrogen

No

No

Compressed Natural Gas (CNG)

Yes

No

Liquefied Natural Gas (LNG)

No

No

Propane

Yes

No

Gasoline Vapor

16

NOT NEEDED
Naturally Strong Odor

Royal Netherlands Navy
Hydrogen Safety

Yes

November 18, 2019
16

% gas-to-air volume ratio

Flammability Range

17

75.0%

80
60
40
29

optimal combustion conditions

20

15.0%

10.1%

7.6%
1.4

4.0

5.0

2.1

Hydrogen

Natural Gas

Propane

0

Royal Netherlands Navy
Hydrogen Safety

Gasoline Vapor

Auto-ignition Temperature
1500° F

1,085°F
585 gr C

1,003°F
539 gr C

914°F
490 gr C

1000° F
450°F
254 gr C

500° F

0° F
Hydrogen

18

Natural Gas

Propane

Royal Netherlands Navy
Hydrogen Safety

Gasoline Vapor

Relative Vapor Density

Relative to Air

5
4

Hydrogen’s low vapor density
results in the gas being very buoyant compared to other fuels and vapors.

4

3
2

1.52

1
0.07

0.55

0
Hydrogen

19

Natural Gas

Propane

Royal Netherlands Navy
Hydrogen Safety

Gasoline Vapor

Comparison Flammability limits

20

Royal Netherlands Navy
Hydrogen Safety

Flammability limit

21

Royal Netherlands Navy
Hydrogen Safety

Flammability limits/
Explosion limits

22

Royal Netherlands Navy
Hydrogen Safety

Hydrogen Hazards

23

Royal Netherlands Navy
Hydrogen Safety

18 november 2019

Ref: ISO 15196
The primary hazards and issues:
Flammability:
 Thermal effects;
 Pressure effects;
 Easy ignitability of some mixtures;
Small size of the molecule:
 Low viscosity;
 High diffusion rate;
 High buoyancy;
24

Royal Netherlands Navy
Hydrogen Safety

The primary hazards and issues (continued):
Interactions with materials (embrittlement of certain metals);
Asphyxiation hazard if oxygen is replaced;
Hazards associated with the storage procedure:

 elevated storage pressure for gas;
 low temperature for cryogenic liquid;
 others for other methods, like metal hydrides.
25

Royal Netherlands Navy
Hydrogen Safety

Designing Safe Systems – Gaseous Hydrogen
Characteristic

Potential Hazard

Control

• Colorless

• Impossible for human
senses to detect

• Detection sensors

• Low Viscosity

• High leak rate

• Leak detection systems

• Very small molecule
(can be absorbed into
materials)

• Embrittles certain
materials; can result in
structural failure

• Ventilation

• Low Volumetric Energy
Density

• Stored at high pressures

• Storage container design

• Odorless
• Tasteless

26

• Material selection

• Pressure-relief devices
Royal Netherlands Navy Hydrogen Safety

Designing Safe Systems – Gaseous Hydrogen
Characteristic

Potential Hazard

Control

• Asphyxiant

• Potential for accumulation
in confined spaces (any gas that displaces oxygen in sufficient concentrations will not support life)

• Ventilation

• Can ignite or explode over
a wide range of
concentrations; leaks of all sizes are a concern

• Ventilation

• Wide flammability range
(4% – 75%)

27

• Leak-detection systems

• Leak-detection systems

Royal Netherlands Navy
Hydrogen Safety

Designing Safe Systems – Gaseous Hydrogen
Characteristic

Potential Hazard

Control

• Low ignition energy

• Minimal energy (small
spark) can ignite

• Ventilation
• Grounding
• System design/removal of possible ignition sources

• Burns with a pale blue
flame that is nearly
invisible in daylight and does not produce smoke

• Potential for undetected
flame

• Flame detectors

• Low heat emission

28

Royal Netherlands Navy
Hydrogen Safety

Designing Safe Systems – Liquid Hydrogen
Characteristic

Potential Hazard

Control

• Low liquefying
temperature (-423°F/253°C)

• Cryogenic burns

• System design

• Lung damage

• Leak-detection systems

• Rapid phase change from
liquid to gas

• Over-pressurization

• Personal protective
equipment
• System design • Pressure-relief devices • Ventilation

• Spill may cause liquid
oxygen to form on asphalt surface 29

• Shock-sensitive surface
area

• Ventilation

Royal Netherlands Navy
Hydrogen Safety

Risk Assesment

30

Royal Netherlands Navy
Hydrogen Safety

Prevention of ignition sources
Each material design needs to be assessed in its own design as per EU directive 94/9/EC & 2014/34/EU (ATEX 114) Each system use needs on its work place needs to be assessed in its own use as per EU directive 1999/92/EC (ATEX 153) Documented in an Explosion safety document:
- AtEx zoning - Ignition analysis - Risk Assesment results - Action registers 31

Royal Netherlands Navy
Hydrogen Safety

18 november 2019

Project risk control

32

Royal Netherlands Navy
Hydrogen Safety

Safety Management System
1. Danger
Identification

2. Risc
Assessment
Risc
Management

What can go wrong?

4. Improvements

What improvement/ mitigations are
required?

What is the root cause?

3. Control
What can I do to prevent it happening if it goes wrong? Is it sufficient? How effective are the controls elements?

Risc = Probability x Exposure x effect
33

Royal Netherlands Navy
Hydrogen Safety

Hiërarchal Danger reduction (ALARP)
Most effective

Elimininate
Replace
Isolate/Seperate
Technical Solution Organisation Procedures

Least effective
34

PPE
Royal Netherlands Navy
Hydrogen Safety

Prevention of ignition sources
Document into Explosion Safety Document Use of NPR 7910-1 guideline in 7 step approach:
1. Is a flammable liquid or gas present?
2. Are limited quantities established or is there a basis for zoning useful?
3. Which kind of danger sources are 4. Is ventilation present 5. Apply AtEx zoning 6. Estimate leak quantities 7. Determine zoning distances 35

Royal Netherlands Navy
Hydrogen Safety

AtEx zoning

36

Royal Netherlands Navy
Hydrogen Safety

Meteodata (Ref Den Helder de Kooy)
Average year temp. DHR 10 gr C Airpressure 1014.9 Hpa Humidity: 78% (12 uur ‘s middags) Calculations done:
Blow down time, Max length gasplume with 4% LEL, Jet Flame, Heatflux, Explosion effects Case 6 (Hydrogen Storage 200 bar, 50 ltr) Case 1 mm lekkage (pin hole) Case 3 mm lekkage (line break) 37

Royal Netherlands Navy
Hydrogen Safety

Engineering volume, mass & TNT equivalent for 200 Bar, 50 ltr gas storage

38

Royal Netherlands Navy
Hydrogen Safety

200 Bar 50 ltr 1mm leak Blow downtime

200 Bar 50 ltr 1 mm leak Gasplume

200 Bar 50 ltr 1 mm leak Temperature Jet Flame

39

Royal Netherlands Navy
Hydrogen Safety

Safety plot Heatflux for jetflame 200 bar 50 ltr tank, 1 mm leak

Legend:
1 KW/m2 personnel
3 KW/m2 first aiders 10 KW/m2 effect buildings 35 KW/m2 lethal 40

Royal Netherlands Navy
Hydrogen Safety

200 Bar 50 ltr 3 mm leak Blow downttime 200 Bar 50 ltr 3 mm lek Gasplume

200 Bar 50 ltr 3 mm leak Temperature Jet flame

41

Royal Netherlands Navy
Hydrogen Safety

Safety plot Heatflux for jetflame 200 bar 50 ltr tank, 3 mm leak

Legend:
1 KW/m2 personnel
3 KW/m2 first aiders 10 KW/m2 effect buildings 35 KW/m2 lethal 42

Royal Netherlands Navy
Hydrogen Safety

Overview Gasplume/ Jetflame effect results
200 Bar, 50 ltr storage Case 6

Blow
down
tijd
[s]

Leak
[mm]

Dist
plume
[m]

Dist
Dist
jetflame lethal
[m]
[m]

Dist
Bldg
[m]

Dist
First Aider
[m]

Dist
personel
[m]

Pin
hole

470

1

4.2

1.8

1.8

1.9

2.2

2.8

Line
break

52

3

13

6

6

6.5

7

9.5

Reference

43

Royal Netherlands Navy
Hydrogen Safety

BST method

Distance applied via Baker-Strehlow-Tang
method via interpolation from datatabel en graphics:

(Ref: ProcessSafetyProgress_v18_p235to240 1999 “A New Set of Blast Curves from Vapor Cloud Explosion”

44

Royal Netherlands Navy
Hydrogen Safety

AtEx ignition analysis

45

Royal Netherlands Navy
Hydrogen Safety

EN1127-1

Ignition analysis EN1127-1 1/3
Potential ignition source

5.1

Hot Surfaces

5.2

Flames and hot gasses

5.3

Mechanical cause sparks

5.4

Electrical Installations

5.5

Electrical circulation currents, kathodic

Equipment Surrounding

corrosion protection
5.6

46

Static electricity

Royal Netherlands Navy
Hydrogen Safety

EN1127-1

Ignition analysis EN1127-1 2/3
Potential ignition source

5.7

Lightning strikes

5.8

Electric Magnetic fields 9 kHz - 300 GHz

5.9

Elektromagnetic radiation within the reach of

Equipment Surrounding

frequency from 300 GHz - 3 x 106 GHz or
waves 1000 μm - 0,1 μm (optical spectrum 5.10

Ionic radiation

5.11

Ultrasound

5.12

Adiabatic compression

5.13

Exo thermal reactions

47

Royal Netherlands Navy
Hydrogen Safety

Use of equipment
within AtEx zone

48

Royal Netherlands Navy
Hydrogen Safety

Used equipment in the field

Flirr thermal imaging camera
49

Royal Netherlands Navy
Hydrogen Safety

Used equipment in the field

Safety lamp
50

Royal Netherlands Navy
Hydrogen Safety

Learned lessons from incidents

51

Royal Netherlands Navy
Hydrogen Safety

Consequenties van
explosies
Older incidents:
• Propane fire and explosions, Dallas • Explosion at a chemical plant producing rocket fuel, Nevada • Fire and explosion (domino effect) at a cracking unit on a refinery site (3rd September 2000, Gonfreville l’Orcher, Havre, France).
• Explosion and fire at a chemical plant (8th June 1988, Auzouer-en-Touraine, France) • Massive explosion at a polyethylene production plant (23rd October 1989, Pasedena, Texas, USA) • Pressurized hydrogen tank rupture: a tank containing 100m3 of hydrogen at 45 bar pressure burst without any apparent reason (1991, Hanau, Frankfurt, Germany) Recent:
• Hydrogen tank explosion kills 2 in Gangneung 23 mei 2019 • Hydrogen Gas Explosion and Fire at Air Products and Chemicals, Inc. in Santa Clara 3 Juni 2019 no injuries • Recent explosions shutdown hydrogen vehicle refueling in NorCal and Norway 11 Juni 2019 No injuries

https://odin.jrc.ec.europa.eu/giada/
52

Royal Netherlands Navy
Hydrogen Safety

Application of the Hazid methodology

53

Royal Netherlands Navy
Hydrogen Safety

What is a Risc?
Risc
=
Probability x Exposure x Effect

54

Royal Netherlands Navy
Hydrogen Safety

Objective of the Hazid
The objectives of the HAZID procedure are to identify main hazards, to review the effectiveness of selected safety measures and, where required, to expand the safety measures in order to achieve a tolerable residual risk.
In compliance with the Seveso II Directive, besides facility safety concepts for new installations, also safety concepts for existing operational facilities have to be reviewed.

55

Royal Netherlands Navy
Hydrogen Safety

Brainstorm sessions/
Check list guidewords

56

Royal Netherlands Navy
Hydrogen Safety

18 november 2019

ALARP
Demonstration
Reduce risk before
mitigation towards after mitigation

57

Royal Netherlands Navy
Hydrogen Safety

Documentation
Hazid register
RI&E
Action plan/Action register Hazid report Explosion Safety document

58

Royal Netherlands Navy
Hydrogen Safety

Bow Tie
Spill onto soil

Liquid Hydrogen Storage

Spill on water

Cryo Hydrogen pumping

Fire
Hydrogen Liquid/Gas
quid Hydrogen transfer

Flash fire/ Explosion

en Liquid to Gas Vaporizer

Loss of containment
Atmospheric Dispersion

Gas Hydrogen Storage

Fire

Gas compression

Atmospheric Dispersion

Gas Hydrogen transfer

Explosion

ydrogen usage in fuelcell

BLEVE Fireball

59

Royal Netherlands Navy
Hydrogen Safety

Risico matrix

60

Royal Netherlands Navy
Hydrogen Safety

More course material:
www.h2tools.org
https://www1.eere.energy.gov/hydrogenandfuel cells/ https://www.hydrogen.energy.gov/training/code _official_training/ https://knowhy.eu/ https://hysafe.org 61

Royal Netherlands Navy
Hydrogen Safety

This text was extracted from the file above so that the document can be found through the search. The PDF is the original and the authoritative version.